Description
Product Application:
Concrete pressure queer according to the international GB/T500 80-2002 standard production, mainly used to determine the concrete at a certain pressure state of the water, and then calculate the water queer rate and pressure water queer ratio.
Main technical parameters and their specifications:
- Maximum number of pressure gauges: 6Mpa
- Minimum degree separation: not more than 0.1 MPa
- Cylinder diameter: 125+0.02mm
- High in the cylinder: 200 + 0.2mm
- Working Piston Diameter: 125mm
- Working piston pressure: 3.2mm
- Screen aperture: 0.335mm (50 mesh)
- Net weight: 20kg