GL-DI 100 Single Combustion Test Equipment for Building Materials

Model Number:

GL-DI 100

Description

Product Application:

 

This test apparatus is used to ascertain the physical characteristics of the ontological test equipment as well as the reflection of the product or building material (except from flooring materials) on the fire in the single combustion test.

 

Main technical parameters and their specifications:

 

  • System temperature measurement range: 0 ~ 400 °C, ≤ ± 0.5 °C
  • System differential measurement range: 0 ~ 100Pa (MAX), ≤ ± 2Pa
  • Emission flow measurement range (fan exhaust): 0.25m3/s ~ 0.8 m3/s (MAX), ≤ ± 1.5% F·S
  • Mass flowmeter measurement range (gas flow): 0 g/s to 3.5 g/s ≤±1% F·S
  • Measurement range of oxygen relative concentration (O2 for air): 16% to 21%, 100 × 10 ^ -6
  • CO2 relative concentration measurement range (CO2 for air): 0% to 10%, 100 × 10 ^ -6
  • Flue transmission rate: 0% to 99.9% ≤ ±1.5% F·S
  • Main (sub) burner ignition method: automatic high-voltage electronic igniter
  • Safety factor 1: explosion-proof switch solenoid valve
  • Safety Measures 2: High Frequency Response Flame Detector
  • Safety factor 3: High-frequency electronic igniters
  • Safety measures 4: domestic well-known brand gas hose
  • Safety 5: Full flame detection software monitoring
  • Combustion chamber covers area: 3200×3200×4300(mm)
  • Control cabinet computer table: 1200 x 800 × 2000 (mm)
  • Flue gas treatment system: microfabrication of water mist swipe flue gas treatment
  • Total system power: 380V, 5Kw, equipment cable length extension equipment 2m
  • Box: Full steel frame, paint plate, plasterboard
  • The system does not contain calibration oxygen, carbon dioxide and propane cylinders for testing (due to transport)

Application

This test apparatus is used to ascertain the physical characteristics of the ontological test equipment as well as the reflection of the product or building material (except from flooring materials) on the fire in the single combustion test.

Specification

System temperature measurement range: 0 ~ 400 °C, ≤ ± 0.5 °C

System differential measurement range: 0 ~ 100Pa (MAX), ≤ ± 2Pa

Emission flow measurement range (fan exhaust): 0.25m3/s ~ 0.8 m3/s (MAX), ≤ ± 1.5% F·S

Mass flowmeter measurement range (gas flow): 0 g/s to 3.5 g/s ≤±1% F·S

Measurement range of oxygen relative concentration (O2 for air): 16% to 21%, 100 × 10 ^ -6

CO2 relative concentration measurement range (CO2 for air): 0% to 10%, 100 × 10 ^ -6

Flue transmission rate: 0% to 99.9% ≤ ±1.5% F·S

Main (sub) burner ignition method: automatic high-voltage electronic igniter

Safety factor 1: explosion-proof switch solenoid valve

Safety Measures 2: High Frequency Response Flame Detector

Safety factor 3: High-frequency electronic igniters

Safety measures 4: domestic well-known brand gas hose

Safety 5: Full flame detection software monitoring

Combustion chamber covers area: 3200×3200×4300(mm)

Control cabinet computer table: 1200 x 800 × 2000 (mm)

Flue gas treatment system: microfabrication of water mist swipe flue gas treatment

Total system power: 380V, 5Kw, equipment cable length extension equipment 2m

Box: Full steel frame, paint plate, plasterboard

The system does not contain calibration oxygen, carbon dioxide and propane cylinders for testing (due to transport)

Inquiry / Request for Quotation