GL-DI 1821 Building window and window insulation performance testing equipment

Model Number:

GL-DI 1821

Description

Product Application:

 

The insulation performance testing apparatus for doors and windows is based on the insulation performance testing apparatus for energy-saving building components as well as the insulation performance testing apparatus for doors and windows that was created in compliance with the standard GB/T8484-2020.

 

Main technical parameters and their specifications:

 

  • Thermal box temperature range: 17 ~ 50 °C, measurement accuracy: 0.2 °C, temperature fluctuation range: 0.01 ~ 0.1 °C
  • Cold box temperature range: -21 ~ -10 °C, measurement accuracy: 0.2 °C, temperature fluctuation range: 0.01 ~ 0.2 °C
  • The surface temperature control accuracy of the outer wall of the hot box: 0.2 °C, measurement accuracy: 0.2 °C
  • Heat box power measurement and control range: 10 ~ 900W, measurement accuracy: 0.2 level
  • Hot box steady state power fluctuation range: ≤0.3 ~ 3W
  • Hot box humidity control range: ≤20%
  • Test efficiency:
    • Intermittent test piece test: refers to the non-intervention test of a test piece total time: 9 ~ 10 hours / piece
    • Continuous test: refers to a period of time, the total time of continuous testing of the same or different specimens: 8 ~ 9 hours / piece
  • With power: AC 380V, power ≤ 8kW, three-phase five-wire system
  • Control mode: computer control, automatic data acquisition, print test report, original record, sampling record (A4 paper)
  • Box structure: cold, hot box respectively open the door, easy to test parts clamping, easy to test parts (or filler) hot and cold surface arrangement temperature sensor. Note: The single-open box construction cannot achieve the above operation.)

Application

The insulation performance testing apparatus for doors and windows is based on the insulation performance testing apparatus for energy-saving building components as well as the insulation performance testing apparatus for doors and windows that was created in compliance with the standard GB/T8484-2020.

Specification

thermal box temperature range: 17 ~ 50 °C, measurement accuracy: 0.2 °C, temperature fluctuation range: 0.01 ~ 0.1 °C

cold box temperature range: -21 ~ -10 °C, measurement accuracy: 0.2 °C, temperature fluctuation range: 0.01 ~ 0.2 °C

the surface temperature control accuracy of the outer wall of the hot box: 0.2 °C, measurement accuracy: 0.2 °C

heat box power measurement and control range: 10 ~ 900W, measurement accuracy: 0.2 level

hot box steady state power fluctuation range: ≤0.3 ~ 3W

hot box humidity control range: ≤20%

Test efficiency:

intermittent test piece test: refers to the non-intervention test of a test piece total time: 9 ~ 10 hours / piece

Continuous test: refers to a period of time, the total time of continuous testing of the same or different specimens: 8 ~ 9 hours / piece

with power: AC 380V, power ≤ 8kW, three-phase five-wire system

control mode: computer control, automatic data acquisition, print test report, original record, sampling record (A4 paper)

box structure: cold, hot box respectively open the door, easy to test parts clamping, easy to test parts (or filler) hot and cold surface arrangement temperature sensor. Note: The single-open box construction cannot achieve the above operation.)

Inquiry / Request for Quotation

Have a question or need a quotation? Fill in the form below and we’ll be in touch soon.