Product Application:
The penetration resistance method is the primary method used by the concrete penetration resistance meter to calculate the concrete’s condensation time. This product works with a variety of cement types, additives, concrete mixers, and matching ratios in a range of temperature conditions.
Main technical parameters and their specifications:
- Display: Pointer
- Maximum measurement value N: 1200
- Test material mold caliber mm: Φ160
- Test material under the caliber mm: Φ150
- Test material mold height mm: 150
- Into the depth of mm: 25
- Minimum value of N:1
- Figure error N: ±10
- The stylus load area is squared mm2:100; 50; 20
- Into the resistance MPa: 0.2 to 3.5; 3.5 to 20; 20 to 28
- Dimensions mm: 700 x 350 x 1000
- Package size mm: 730 x 360 x 1040
- Weight of kg: 40