Description
Product Application:
The GB/T11944-2012 standard states that advanced refrigeration technology can quickly lower the copper cold probe to less than -60 °C, making it suitable for laboratory testing of insulating glass dew points in buildings. High-precision instruments automatically regulate the test temperature.
Main technical parameters and their specifications:
- Temperature of the cold probe: <-60 °C
- Temperature resolution: 0.1°C
- Accuracy of temperature measurement: ±0.5°C
- Voltage: AC 220V, 50HZ
- Total power: 1.5kW
- Dew point meter control box size: 900 × 650 × 900mm
- Weight of kg: 200